Peer Review
Cancer Imaging
ISSN 1470-7330
Search site with:PicoSearch


Content
Current Issue
Archive
Related Journals / Articles
Information
Aims and Scope
Editors and Board
Editorial Policy
Instructions for Authors
Copyright Transfer Form
Subscription Information
Advertising
Society
Aims
Membership
Annual Meeting
Communications
Bulletin Board
Send Email to ICIS
e-Med
Visit e-Med Web Site
Journals
Purchase
“To Promote Education in Cancer Imaging in the Multidisciplinary Management of Malignancy”

Home > Articles

Prognostic value of angiogenesis evaluated with high-frequency and colour Doppler sonography for preoperative assessment of primary cutaneous melanomas: correlation with recurrence after a 5 year follow-up period Open Access Article

Abstract

Objective: To study the value of high-frequency sonography (HFS) and colour Doppler sonography (CDS) in evaluating the 5 year metastatic potential of primary cutaneous melanomas (CM). Materials and methods: 111 CM were studied before surgical resection and 107 were depicted on HFS. The maximal HFS thickness was measured and compared with the Breslow thickness. A CDS study was performed in each tumour. Results: HFS thickness ranged from 0.26 to 8.0 mm and Breslow thickness from 0.15 to 8.0 mm. HFS and Breslow thickness correlated strongly (r > 0.93). Intratumour vessels were depicted in 43 of the 107 CM, of which 40 were thicker than 2 mm. The median follow-up was 61 months and 27 patients developed relapses. In the univariate analyses, neovascularization visualized with CDS, sonographic thickness and the Breslow thickness were significantly linked to relapses (p < 0.0001), as were lymph node status and ulceration (p = 0.007 and 0.004). Conclusion: Vascularization was observed mainly in thick primary melanoma. A median follow-up of 5 years showed the prognostic value of angiogenesis evaluated by CDS.

Author

Nathalie Lassau, Michele Lamuraglia, Serge Koscielny, Alain Spatz, Alain Roche, Jerome Leclere and Marie-Francoise Avril

Contact Details

Corresponding address:
Nathalie Lassau,
39 rue Camille Desmoulins,
94805 Villejuif Cedex,
France

Reference

ICIS Cancer Imaging Volume 6 Issue 1
DOI: 10.1102/1470-7330.2006.0009

Date Posted

25 April 2006


Open Access Article Open Access is provided for this article.

Screen PDF

Size

352.46 KB

Minimum Estimated Download Times

ADSL 2Mb/s (Broadband):

1 second

ADSL 512Kb/s (Broadband):

5 seconds

64 Kb/s (ISDN):

44 seconds

33.3 Kb/s (Typical Modem):

1 minute 24 seconds

Print PDF

Size

685.39 KB

Minimum Estimated Download Times

ADSL 2Mb/s (Broadband):

2 seconds

ADSL 512Kb/s (Broadband):

10 seconds

64 Kb/s (ISDN):

1 minute 25 seconds

33.3 Kb/s (Typical Modem):

2 minutes 44 seconds

No part of this publication or site may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of the Publisher, e-MED Limited, Permissions, PO Box 61053, London, SE16 7YZ. Tel: +44 (0)207 719 8989 Fax: +44 (0)560 126 4446, permissions@cancerimaging.org.

© 2000-2009 International Cancer Imaging Society